OPW 1500 Automatic Tank Gauging System

High quality. Low cost. That’s what you get with the OPW 1500 Automatic Tank Gauging System. The 1500 gives you everything you need for enhanced compliance. The Segmented Leak Detection feature allows you to perform in-tank leak testing continuously without having to shut down your tanks. SmartTalk™, OPW’s enhanced fuel management software combines tank and compliance information for accurate management of multiple fueling sites from your central office.

OPW 1500 Automatic Tank Gauging System

OPW 1500 Tank Gauging System

OPW 1500 Tank Gauging System

Click to view alternate images.

  • Features & Benefits
  • Technical Specifications
  • Downloads

OPW 1500 Tank Gauging System Features

  • Connectivity SmartTalk™ software connects fuel tanks with back-office computers, providing enhanced inventory and compliance management for multiple sites
  • Automated - Segmented Leak Detection (SLD) software provides continuous testing so 24-hour operations never have to shut down for 0.2 gph compliance testing
  • Convenience - Automatic reports: Delivery, Inventory, Alarm Status, Leak Test history and more
  • Intuitive - Diagnostic codes displayed on the console tell service technicians what is wrong
  • Backlit LCD display
  • Alphanumeric keypad
  • Continuous monitoring for up to 4 tanks
  • Console diagnostic codes
  • Rolling 250-event troubleshooting history

Regulatory Compliance

  • Segmented Leak Testing (SLD) for 24-hour sites 
  • For tanks, sumps, wells, lines
  • Programmable leak tests (daily, weekly, monthly, continuously, or on demand) 
  • Selectable leak rates 0.2 gph (0.76 lph), 0.1 gph (0.38 lph) 
  • Automatic notification of compliance deadlines

Inventory Management

  • Fuel height and volume
  • Shift reports
  • Automatic fuel delivery reports

Reporting Capabilities

  • Shift reports can be programmed to be stored automatically three times daily. The information can be displayed via the on-site computer, off-site computer or printed on the system printer.
  • On-demand reports: Inventory Status, Shift Report, Delivery Status, Alarm Status, Sensor Status, Generator Usage History, Event History, Leak Test History

Self-monitoring Capabilities

  • Designed to minimize service time and costs
  • Rolling 250-event detailed history aids in trouble shooting

Comprehensive Programmable Alarms

  • High Product
  • Low Product
  • High Water
  • Theft
  • Leak Test Failed
  • Leak Test Required
  • Modern auto-dial feature sends alarms to remote computer automatically

Stand-by Generator

  • Programmable option available in standard software
  • Generator usage and history reports, including start time, stop time, and fuel usage provided after generator operation
  • System handles a mix of standard and stand-by generator tanks at the same time

Serial Communications

  • Local and modem ports standard

Listings & Certifications

  • Dimensions:  13”W, 11.25”H, 6”D (33  x 28.6  x 15.25 cm)
  • Weight: 15 lbs.
  • Operating Temperature: 32º F  to 104º F (0º C to 400º C)
  • Humidity: 90% non-condensing
  • Typical Mounting Location: Protected, non-hazardous area
  • Power Requirements: 120 VAC ± 10%, 60 Hz.
  • 15-amp dedicated circuit
  • Listings and Approvals: CSA, ETL
  • System Relay: 10 amp, 250 VAC contacts
  • RS-232 (optional): 2 ports (modem and local)
  • Relays: 1 standard, 4 optional

TLM Specifications

  • Number of Tanks: Up to 4
  • Probe Inputs: Intrinsically-safe magnetostrictive
  • Probe Power Supply: 26 VDC
  • Level Precision: ± 0.0005” (0.0013 cm)
  • Level Accuracy: ± 0.04% full scale
  • Temperature: ± 0.50º F (± 0.30º C)
  • 0.2 gph (0.76 lph) Static Leak Test: 99% Pd, 1% Pfa
  • 0.2 gph (0.76 lph) Continuous Leak Test: 99.1% Pd, 0.9% Pfa
  • 0.1 gph (0.381 lph) Static Leak Test: 99% Pd, 1% Pfa
  • EPA Leak Test Certified: 15,000-gallon tank (56,781 liters) for static tests 35,000-gallon tank with SLD (132,475 liters) for single or manifold tanks

Probe Specifications

  • Type: Magnetostrictive/Float
  • Material: Stainless steel shaft
  • Location: Hazardous, Class 1, Division 1, Group D
  • Temperature: 5 RTDs
  • Temperature Range: -40º F to 158º F (-40º C to 70º C)
  • Data Cable: Up to 250’ (76 m) use Belden 8760; 250’ to 1000’ (76 m - 304 m) use Belden 9182

Leak Sensor Specifications

  • Number of Sensors: Up to 8
  • Sensor Types: OPW discriminating and non-discriminating sensors
  • Discriminating Dispenser Pan: Q0003-001
  • Discriminating STP Sump: Q0003-002
  • Discriminating Interstitial: Q0003-003
  • Discriminating Monitoring Well: Q0003-104 10’ (3 m)Q0003-154 15’ (4.5 m), Q0003-204 20’ (6 m)
  • Wet Interstitial: Q0003-005
  • Liquid-only Interstitial: Q0003-006
  • Liquid Float: Q0003-009