FIT500™ System

The FIT500™ system combines leading-edge technology with a futuristic look and solid stainless steel durability, creating an unequalled 24-hour fuel management system with the quality and reliability that Petro Vend is renowned for.

With the ability to add customizable screen images out at the fuel island, the FIT500™ is the ultimate fuel management system for advertising special promotions inside the store and for strengthening your brand identity.

Download the FIT500™ Catalog Page

FIT500&trade

FIT500&trade

Click to view alternate images.

  • Features & Benefits
  • Technical Specifications
  • Downloads

Features

  • Powerful fuel control system for the petroleum marketer or fleet owner
  • The latest electronic design with rock-solid durability to create a cutting edge, 24-hour unattended fueling system
  • Stainless steel enclosure for years of maintenance-free operation
  • Dual-head card reader
  • High-speed, auto-loading, thermal receipt printer with graphics capability
  • Impressive 10.4 inch (26.4 cm) graphics color display
  • Add custom color graphics to your screen images with a simple USB memory key
  • Separate alpha, numeric, and function key pads are backlit for easy viewing at night
  • Supports a multitude of commercial fueling cards, truck fleet cards and major bank cards
  • System is field-upgradeable so you can easily add network interfaces remotely
  • Ideal for marine and ethanol fueling applications
  • USB memory key for transaction backup/transfer and updating card files
  • Optional dial-up or cell modem allows communication to remote locations
  • Each FIT500™ can also be outfitted with 802.11 WiFi or Bluetooth® communication devices to facilitate updates and retrieval of transaction data

Benefits

  • Profitability - Accepts the widest selection of fueling network and major bank cards
  • Customize - Customizable color screen images enhance your marketing programs and activities
  • Installation - Integrated FSC3000™ for installations where no building is available. USB key for transaction backup and card file updates
  • Communication - Optional 900 MHz wireless communication between island and building. Cell modem, Bluetooth® and 802.11 WiFi communication also available
  • Change receipt paper without opening the FIT500™ enclosure
  • Windows-based ARTWare™ PC software makes programming simple and provides system backup
  • Remotely download software updates to the FSC3000™
  • USB memory key for transaction data storage and card updates
  • Connects with OPW and many other tank gauges
  • Pump and product totals automatically or on demand
  • System and/or dual card (driver and vehicle) operation
  • Cardless operation for either driver, vehicle or both
  • Drivers and vehicles can be grouped into accounts for easier control of group restrictions, lockouts and reporting
  • Daily and monthly credit allocations per card or account

    Networks

    • The FIT500™ System interfaces with many authorization and commercial fueling networks to accept the following cards:
      • CFN
      • Wright Express
      • Comdata
      • Voyager
      • EFS
      • TCH
      • Fuelman/Gascard
      • Bank Cards
      • T-Chek
      • FleetOne
    • Dual network option reduces wait time by accessing two networks simultaneously
    • Registered bank card feature enables secure use credit cards even where unattended fuel may be restricted
    • The FIT500™ System is field-upgradeable so you can easily add network interfaces to meet any needs

    Memory

    • Standard memory 2,000 proprietary cards, and 500 transactions
    • Expandable to 64,000 proprietary cards, and 2,000 transactions

    Pump Control Methods

    • Pump Control Modules for Commercial Dispensers with mechanical registers
      • Mounted in Fuel Island Terminal for low-cost, convenient wiring
      • Mounted in remote cabinet
      • Pump Handle Monitor
      • Manual bypass for each dispenser
      • Four adjustable fueling timers
        • Maximum fueling time
        • Maximum time to activate pump handle
        • Maximum time until first pulse
        • Maximum time between pulses
      • Counts in gallons or litres from thousandths to full units
      • Pump sentry provides protection from faulty pulsers
    • Direct Pump Control communicates via serial link to the dispensers (Optional)
      • Supports Wayne, Gilbarco and Tokheim protocols
      • Extremely simple installation
    • Universal Pump Controller for operation with a pump controller (Optional)
      • Interfaces with Wayne, Gilbarco and Tokheim
      • Allows pumps to be controlled via the Fuel Island Terminal or retail pump console

    Phoenix™ Software

    • Phoenix™ Plus – poll transactions, perform card updates, run reports
    • Phoenix™ Premier – all of the Phoenix™ Plus features, plus tank gauge interface for reconciliation

    Listings & Certifications

    FIT500™ Fuel Island Terminal Specifications

    • Reader: Magnetic-stripe Card with dual read heads
    • Display: 10.4" (nominal size), Active Matrix VGA Color Display
    • Receipt Printer: The high-resolution, thermal receipt printer has an integrated cutter and large paper roll
    • Keypads: The keypads are durable and weather-resistant
    • Cabinet Dimensions: 20" H x 17-3/4" W x 11-3/8" D (38 cm H x 46 cm W x 28 cm D)
    • Pedestal Dimensions: 42" H x 17-3/4" W x 9" D (122 cm H x 36 cm W x 20 cm D)
    • Operating Temperature Range: -40° F to 122° F (-40° C to 50° C)
    • Power Requirements: 120/240 VAC (auto-detectable), 50/60 Hz; 250 watts max.

    Pump Control Terminal Specifications

    • Relay Rating: 1 HP, 120/240 VAC
    • Pulser Compatibility: Contact/12 VDC Electronic
    • Pulser Power Supply: 12 VDC; 40 milliamps max./pulser
    • Pulser Speed: 6,000 pulses/minute (mechanical), 100,000 pulses per minute (electronic)
    • Pulser Rate: 1:1 to 9,999:1 (in one-pulse increments)
    • Pulser Type: Single channel
    • Pulser Duty Cycle: 50%
    • Operating Temperature Range: -40° F to 122° F (-40° C to 50° C)
    • Cabinet Dimensions of Wall-mounted remote PCM: 11.5" H x 12" W x 6.5" D (29 cm H x 30 cm W x 16 cm D)
    • Power Requirements of Remote PCM: 85-240 VAC, 50/60 Hz; 25 watts max.
    • Operating Temperature Range of Remote PCM: -40° F to 122° F (-40° C to 50° C)

    FSC3000™ Fuel Site Controller Specifications

    • Dimensions: 2" H x 10" W x 11" D (5 cm H x 25 cm W x 28 cm D)
    • Power Requirements: 85-240 VAC, 50/60 Hz; 25 watts max.
    • Operating Temperature Range (indoors): 32° F to 122° F (0° C to 50° C)
    • Serial Communication Ports: Petro-Net™ (RS-485), Printer (RS-232), Terminal (RS-232), Modem (RS-232), Pass-through (RS-232), 2 Auxiliary Ports (RS-232), Tank Gauge, Ethernet, USB Maximum Petro-Net™ Distance: 5,000 feet (1,524 m)